FQ SERIES PHOTOELECTRIC FIBER SENSOR |
||
SN | SN=see fiber options | |
Functions: | Teach-in | |
Timer | ||
Programed | ||
House Size: | 30x65x10mm |
FQ SERIES PHOTOELECTRIC FIBER SENSOR SPECIFICATIONS | ||
Type/Item | NPN Output | PNP Output |
Supply voltage | 10 to 30V DC Ripple P-P 10% or less | |
Power consumption | Normal operation: 960mW or less(current consumption 40mA or less at 24V supply voltage) ECO mode: 960mW or less(current consumption 25mA or less at 24V supply voltage) |
|
Output | NPN open-collector transistor Max sink current:100mA Applied voltage:30V DC or less ¡¤Residual voltage:1.5V or less at 100mA |
PNP open-collector transistor Max source current:100mA Applied voltage:30V DC or less ¡¤Residual voltage:1.5V or less at 100mA |
Output operation | Light-ON or Dark-ON, selectable with jog switch | |
Short-circuit protection | Yes | |
Response time | 150¦Ìs or less, 250s or less, 2.0ms or less,selectable with jog switch | |
Display |
4 digit LED display | |
Sensitivity setting |
2-level teaching /Limit teaching/ Manual adjustment | |
Fine sensitivity adjustment function |
Incorporated | |
Timer function |
Incorporated with variable ON-delay/OFF-delay/ONE- SHOT timer, switchable either effective or ineffective | |
Interference prevention function |
Incorporated(up to four fibers can be mounted adjacently) | |
Ambient temperature | -10 ¡ãC to +55 ¡ãC | |
Ambient humidity | 35 to 85% RH, Storage: 35 to 85% RH | |
Emitting element | Red LED( modulated) | |
Material | Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate, Switch: Acrylic | |
Weight | 20g approx. |
MOUNTING | |
How to mount the amplifier | |
¢Ù Fit the rear part of the mounting section of the amplifier on a 35mm width DIN rail. | |
¢Ú Press down the front part of the mounting section of the amplifier on the 35mm width DIN rail. |
|
How to remove the amplifier | |
¢Ù Push the amplifier forward. | |
¢Ú Lift up the front part of the amplifier to remove it. Note: Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break. | |
How to connect the amplifier | |
¢Ù Snap the fiber lock lever down.. | |
¢Ú Insert the fiber cables slowly into the inlets until they stop.(Note1) | |
¢Û Return the fiber lock lever to the original position till it stops. |
FQ SERIES PHOTOELECTRIC FIBER SENSOR CONNECTION DIAGRAM |
____________ |
____________ |
PART DESCRIPTION |
FQ SERIES PHOTOELECTRIC FIBER SENSOR CONNECTION DIAGRAM(mm) | ||
Amplifier(FQ-301P/N...)
|