FQ SERIES PHOTOELECTRIC FIBER SENSOR

SN SN=see fiber options
Functions: Teach-in
  Timer
  Programed
House Size: 30x65x10mm
FQ SERIES PHOTOELECTRIC FIBER SENSOR SPECIFICATIONS
Type/Item NPN Output PNP Output
Supply voltage 10 to 30V DC Ripple P-P 10% or less
Power consumption Normal operation: 960mW or less(current consumption 40mA or less at 24V supply voltage)
ECO mode: 960mW or less(current consumption 25mA or less at 24V supply voltage)
Output NPN open-collector transistor
Max sink current:100mA
Applied voltage:30V DC or less
¡¤Residual voltage:1.5V or less
at 100mA
PNP open-collector transistor
Max source current:100mA
Applied voltage:30V DC or less
¡¤Residual voltage:1.5V or less
at 100mA
Output operation Light-ON or Dark-ON, selectable with jog switch
Short-circuit protection Yes
Response time 150¦Ìs or less, 250s or less, 2.0ms or less,selectable with jog switch
Display
4 digit LED display
Sensitivity setting
2-level teaching /Limit teaching/ Manual adjustment
Fine sensitivity
adjustment function
Incorporated
Timer function
Incorporated with variable ON-delay/OFF-delay/ONE- SHOT timer, switchable either effective or ineffective
Interference prevention
function
Incorporated(up to four fibers can be mounted adjacently)
Ambient temperature -10 ¡ãC to +55 ¡ãC
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Emitting element Red LED( modulated)
Material Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate, Switch: Acrylic
Weight 20g approx.
MOUNTING
How to mount the amplifier
¢Ù Fit the rear part of the mounting section of the amplifier on a 35mm width DIN rail.

¢Ú Press down the front part of the mounting section of the amplifier on the 35mm width DIN rail.

How to remove the amplifier
¢Ù Push the amplifier forward.
¢Ú Lift up the front part of the amplifier to remove it. Note: Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break.
How to connect the amplifier
¢Ù Snap the fiber lock lever down..
¢Ú Insert the fiber cables slowly into the inlets until they stop.(Note1)
¢Û Return the fiber lock lever to the original position till it stops.
FQ SERIES PHOTOELECTRIC FIBER SENSOR CONNECTION DIAGRAM

____________

____________

PART DESCRIPTION
FQ SERIES PHOTOELECTRIC FIBER SENSOR CONNECTION DIAGRAM(mm)

Amplifier(FQ-301P/N...)

Vastly-e @ Copyright (C) 2009 All Rights Reserved